Need some advice? Get in touch today to discuss your needs.

make an enquiry

JP126 Gimbal Expansion Joint Flanged

Specification

Gimbal expansion bellows consisting of stainless steel grade 321 bellows fitted with carbon steel oval flanges drilled to BS 4504 NP16. Complete with carbon steel gimbal ring assembly.

Application

Stourflex gimbal expansion joints are used in sets of two along with angular expansion joints to accommodate complex lateral movements in pipework installations. This movement occurs due to thermal expansion or contraction or building settlement.

They are suitable for use on L.T.H.W., M.T.H.W., H.T.H.W., steam and other hot liquids and gases

  • Maximum working temperature 300ºC.
  • Maximum working Pressure 16 bar at 120ºC.
  • Stourflex gimbal expansion joints should not be used at their maximum working temperature and pressure respectively.
  • Maximum test pressure = 1.5 x working pressure or 1.5 x flange rating whichever the lower.

Please ask for pricing or more information.

Download data sheet
JP126 expansion joint

our technical specifications

Our JP126 Gimbal Expansion Joint Flanged specifications

Part numberN.B. (mm)Angulation (degree)Overall length (mm)Working pressure @120°C (bar)Cold test pressure (bar)
JP126-50-165051331624
JP126-65-166551331624
JP126-80-168051331624
JP126-100-1610051331624
JP126-125-161256.51991624
JP126-150-161506.51991624
JP126-200-1620072121624
JP126-250-1625072121624
JP126-300-1630072121624

Force to angulate available on request.

Stainless steel grade 321 internal flow sleeve fitted as standard.

Where service conditions above 300ºC or 16 bar exist or where additional movement is required non standard variations of the Type JP126 are available if required.

Alternative flange drillings are available. Stourflex gimbal expansion joints are supplied at their maximum overall length and must not be extended. Gimbal expansion joints must be securely anchored and adequately guided to ensure their correct performance. Omitting anchors and guides may result in failure of the system.

All Stourflex products should be installed in accordance with our fitting instructions.

Download data sheet